OM-237 881 Page 43
9-4. Troubleshooting
Trouble Remedy
No weld output; unit completely inop-
erative.
Place line disconnect switch in On position (see Sections 4-9 and 4-10).
Check and replace line fuse(s), if necessary, or reset circuit breaker (see Sections 4-9 and 4-10).
Check for proper input power connections (see Sections 4-9 and 4-10).
No weld output; meter display On. Input voltage outside acceptable range of variation (see Section 4-8).
Check, repair, or replace remote control.
Unit overheated. Allow unit to cool with fan On (see Section 3-4).
Erratic or improper weld output. Use proper size and type of weld cable (see Section 4-4).
Clean and tighten all weld connections.
Check for correct polarity.
No 115 volts AC output at optional du-
plex receptacle or Remote 14 recep-
tacle.
Reset supplementary protector CB1 (see Section 4-6).
No 24 volts AC output at Remote 14
receptacle.
Reset supplementary protector CB2 (see Section 4-6).