OM-237 881 Page 38
8-2. CC Welding Mode - SMAW/CAC-A Process
! Weld terminals are energized
through the remote control in CC
welding mode.
1 Mode Switch
2 Left Display
3 Right Display
4 Amps Indicator
5 Adjust Control
6 Arc Control Indicator
7 Setup Button
Setup
For typical system connections refer to
Section 8-1.
Rotate Mode Switch to CC position as
shown.
The preset amperage is shown in the Right
Display with the Amps Indicator lit.
Operation
While the Amps Indicator is lit under the
Right Display, the Adjust Control is used to
set desired preset amperage.
A remote control is required to turn on the
weld output.
. If the remote control has an amperage
adjustment, the adjustment will func-
tion as a percentage of the preset am-
perage.
Pressing the Setup Button allows adjust-
ment of Arc Control, Hot Start Current and
Hot Start Time.
. For best results at the end of the weld,
pull back the electrode quickly to extin-
guish the arc.
Arc Control (Dig)
Press the Setup Button so the Arc Control
indicator is lit. DIG appears on the Left Dis-
play, and the corresponding dig setting ap-
pears on the Right Display.
Rotate Adjust Control to select desired dig
setting from 0 to 100.
Dig control allows the arc characteristics,
soft versus stiff, to be changed for specific
applications and electrodes. Lower the dig
setting for smooth running electrodes like
E7018 and increase the dig setting for stiff-
er, more penetrating electrodes like E6010.
Press the Setup Button repeatedly until the
Arc Control light goes out to return to ad-
justment of preset amperage.
Programmable Hot Start
Press the Setup button repeatedly until
HOT.S appears on the Left Display. HOT.S
adjusts the Hot Start Amperage to Adaptive
Hot Start (AUTO) or from Min (1) to Max
(50). Adaptive Hot Start (AUTO) automatic-
ally chooses a default amperage. The Min
(1) setting results in no hot start amperage.
Higher numbers result in higher start am-
perage.
Press the Setup button again so HOT.T ap-
pears on the Left Display. HOT.T adjusts
the Hot Start Time to Adaptive Hot Start
(AUTO) or from Min (1) to Max (50). Adapt-
ive Hot Start (AUTO) automatically
chooses a default Time. The Min (1) setting
results in no hot start time. Higher numbers
result in longer start time.
Press the Setup Button to return to adjust-
ment of preset amperage.
. Use this mode for Air Carbon Arc
(CAC−A) cutting and gouging. For best
results, adjust dig setting to maximum.